CHECKING GAS
CONNECTIONS
WARNING:
Test all gas
piping and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
WARNING: Never use an
open flame to check for a leak.
Apply a mixture of liquid soap
and water
to all joints. Bubbles
forming show a leak. Correct all
leaks at once.
Pressure Testing Gas Supply
Piping System
Test Pressures In Excess Of
1/2 PSIG (3.5 K Pa)
1. Disconnect appliance with its
appliance
main
(control valve) and equipment
shutoff valve from gas supply
piping system. Pressures in
excess of 1/2 psig will damage
heater regulator.
2. Cap off open end of gas pipe
where equipment shutoff valve
was connected.
3. Pressurize
supply
s y s t e m
b y
e i t h e r u s i n g
compressed
air
propane/LP supply tank valve.
4. Check all joints of gas supply
piping system. Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Reconnect heater and equipment
shutoff valve to gas supply. Check
reconnected fittings for leaks.
Test Pressures Equal To or
Less Than 1/2 PSIG (3.5 K Pa)
1. Close equipment shutoff valve
(see Figure 14).
2. Pressurize supply piping system
by either using compressed air
or opening propane/LP supply
tank valve.
3. Check all joints from propane/LP
supply tank to equipment shutoff
valve (see Figure 14). Apply
mixture of liquid soap and water
to gas joints. Bubbles forming
show a leak.
4. Correct all leaks at once.
INSTALLATION
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve
(see Figure 14).
2.
Open propane/LP supply tank
valve.
3. Make
heater is in the OFF position.
4. Check all joints from equipment
shutoff valve to control valve
(see Figure 15 ). Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Light
Heater, pages 10,11and 12) Check
gas
valve
the rest of the internal joints for
leaks.
7. Turn off heater (see To Turn Off
Gas to Appliance, pages 11 and
12).
8.
Replace lower front panel.
piping
or
opening
Figure 14 -Equipment Shutoff Valve
Figure 15 -Checking Gas Joints
sure
control
knob
heater
(see Operating
1 0

OPERATING YOUR HEATER

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not
follow
these
exactly, a fire or explosion may
r e s u l t
c a u s i n g
of
damage, personal injury
loss of life.
A When lighting the pilot, follow
these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to
the floor because some gas is
heavier than air and will settle
on the floor .
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately
supplier from a neighbor's
phone.
Follow
supplier's instructions.
If
you
cannot
gas supplier, call
department.
C. Use only your hand to push in
or turn the gas control knob.
Never use tools. If the knob
will not push in or turn by
hand, don't try to repair it, call
a qualified service technician or
gas supplier. Force or attempted
repair may result in a fire or
explosion.
D. Do not use this appliance if any
part has been under water.
Immediately call a qualified
service technician to inspect
the appliance and to replace
any part of the control system
and any gas control which has
been under water.
instructions
p r o p e r t y
or
call
your
gas
the
gas
reach
your
the fire

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml100hpaMl100tpa

Table of Contents