CHECKING GAS
CONNECTIONS
Continued
Pressure Testing Heater Gas
Connections
1. Open equipment shutoff valve
(see Figure 13).
2. Open main gas valve located on or
near gas meter.
3. Make sure no power to heater.
4. Check all joints from equipment
shutoff valve to control valve
(see Figure 14 ). Apply mixture of
liquid soap and water to gas
joints. Bubbles forming show
a leak.
5. Correct all leaks at once.
6. Light
heater
(see Operating
Heater, pages 11 and 12). Check
the rest of the internal joints for
leaks.
7. Turn off gas (see page 12 ).
Figure 13 -Equipment Shutoff Valve
Figure 14 -Checking Gas
Connections

OPERATING YOUR HEATER

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not
follow these instructions exactly,
a fire or explosion may result in
causing property damage,personal
injury or loss of life.
A. This appliance is equipped with an
ignition device which auto matically
lights the pilot. Do not try to light
the pilot by hand.
B. BEFORE LIGHTING smell all
around the appliance area for
gas. Be sure to smell next to
the floor because some gas is
heavier than air and will settle
on the floor .
WHAT TO DO IF YOU SMELL GAS
l Do not try to light any appliance.
l Do not touch any electric switch;
do not use any phone in your
building.
l
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
l
If
you
cannot reach
gas supplier, call the fire
department.
C. Use only your hand to push
on button. Never use tools. If
the does notoperate. don't try to
repair it, call a qualified service
technician or gas supplier.
Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any
p art h as b ee n u n d er w at er.
Immediately call a qualified
service technician
the appliance and to replace
any part of the control system
and any gas control which has
been under water.
OPERATING
INSTRUCTION
For MN200EHBC, MN 300EHBC
models with manual overrside make
sure the Control Knob in the
ELECTRIC postion.(See Figure 15).
1. STOP! Read the safety informa-
tion obove before lighting.
2. Disconnect or turn off all electric
power to heater.
3. This appliance is equipped with
an ignition device which automati-
cally lights the pilot. Do not try to light
the pilot by hand.
11
4. W ait five (5) minutes to clear out
any gas. Then smell for gas, includ-
ing near the floor. If you smell gas,
STOP! Follow "B" in the safety in-
formation above. If you don't smell
gas, go to next step.
5. Plug into a properly grounded three-
prong receptacle, set ON/OFF
switch on, you will hear a high pitch
sound that indicates the burner is
ready to be operated.
6. Make sure Control Knob is in ELEC-
TRIC position.
7. Press IGN/OFF button an electric
spark will ignite the pilot.
8. Press BURNER button for desired
burner operation.
AUTO: Burner will automatically turn
on or off to desired temperature
your
setting, press
temperature setting.
MAN: Burner operates continuously.
OFF:The main burner will shut off.
9. If the appliance will not operate,
follow the instructions "To Turn Off
Gas To Appliance" and call your
service technician or gas supplier.
Note: The thermostat sensing bulb
measures the temperature of air near
the heater cabinet. This may not al-
ways agree with room temperature
to
inspect
(depending on housing construction,
installation location, room size, air
temperatures, etc.) Frequent use of
your heater will let you determine your
own comfort levels.
SETTING CLOCK
Clock setting: Press CLOCK button
to select item (hour, minute). The se-
lected item will flash.
to change to correct time (hour,
minute). Press CLOCK button again,
to set clock.
or
for desired
Press