Equipment Check — X'10'
The following exception codes are the valid codes for an equipment check
condition and apply only to coax attachments:
X'10F100' Permanent Error
Explanation:
1. There was a permanent hardware error.
2. The microcode detected an unrecoverable logic error.
3. The microcode detected a condition that should not have occurred.
Alternate Exception Action: None.
Data Check — X'08'
The following exception codes are the valid codes for a data check condition:
X'082100' Undefined Character
Explanation:
1. An undefined character code has been detected in Write Text data.
2. An undefined overstrike character code has been detected.
3. A character has been detected in Write Text Command data which is
undefined at the quality level specified by the XOA-PQC command.
4. An undefined character code has been detected in Write Bar Code data.
Alternate Exception Action:
For reasons 1-3, print the default character. For reason 4, there is no alternate
exception action.
X'086000' Numeric Representation Precision Check
Explanation:
1. The print position cannot be represented within the printer.
2. The result of the calculation cannot be represented in the printer. This
may result from the WGC GDD window limits being very close together.
3. There was a coordinate overflow while scaling.
Alternate Exception Action: None.