The Command Syntax - Printronix T5000R Series Programmer's Reference Manual

Ipds emulation
Hide thumbs Also See for T5000R Series:
Table of Contents

Advertisement

Chapter
2
The IPDS Emulation
Overlay
Block
Blocks contain images, graphics, bar codes, coded fonts, and text. Each block
is recognized by specific, functional commands. To print a bar code, for
example, Bar Code commands must be in the data stream.
As each type of data block is stored in memory, the printer moves from state
to state. For example, when the printer is reading the Bar Code commands, it
is in the bar code state.
Once all the data has been stored, the page can be closed with an End Page
command and the printer, which is now in the Home State, is ready to print
the page.

The Command Syntax

The commands on the following pages use this syntax:
Byte Count
D6XX
Flag
CID
Data
12
Figure 2. Processing a Page
Byte
D6XX
Flag
Count
A two-byte field. Specifies the length of the command.
A two-byte field. "D6" denotes an IPDS command; "XX" is
the hex code for the IPDS command.
A one-byte field containing the IPDS command stream
flags. You can request an Acknowledgement Required
response from the printer in this field.
Correlation ID. A two-byte field that identifies the
command. If an exception (error) occurs, the printer will
respond with a Negative Acknowledge Reply and the CID
associated with the command.
0-32760 bytes if CID is present;
0-32762 bytes if CID is not present.
This field contains parameters, orders, and data
necessary for implementing the command.
Physical Page
(Medium Presentation
Space)
Logical Page
Page Segment
CID