Printronix T5000R Series Programmer's Reference Manual page 61

Ipds emulation
Hide thumbs Also See for T5000R Series:
Table of Contents

Advertisement

.
X'039201' Image Data Discrepancy
Explanation: There are insufficient or too many bytes of data in the Image
Data order.
Alternate Exception Action: None.
X'039300' Graphic Image Bracket Error
Explanation: An End Image order is executed without a Begin Image order
having been previously executed.
Alternate Exception Action: None.
X'039301' Incorrect Number of Image Data Orders
Explanation: The number of Image Data orders between the Begin Image
and End Image orders is not equal to the number of rows in the image (as
given by the value of height in the Begin Image order).
Alternate Exception Action: None.
X'03C200' Marker Symbol Set Not Available
Explanation: The symbol set identified by the current Marker Set attribute is
not available.
Alternate Exception Action: Use the standard default marker symbol set.
X'03C201' Undefined Marker Code
Explanation: A marker code point is undefined in the current marker symbol
set.
Alternate Exception Action: Use the standard default marker symbol
X'03C300' Character Symbol Set Not Available
Explanation:
1. The symbol set identified by the current Character Set is not available.
2. The current character set specified in the Set Character Set order does
not have the proper attributes to be printed in graphics mode.
Alternate Exception Action: Use the standard default character symbol set.