To Order Model CN77000 SERIES CONTROLLER (Specify Model Number)
PROCESS CONTROLLER, DUAL DISPLAY FOR THERMOCOUPLE, RTD, VOLTAGE OR CURRENT INPUTS IN A 1/16 DIN CASE
Model No. Description
CN77
Dual displays for simultaneous display of measured value and setpoint.
Selectable preset tune, adaptive tune, autotune, PID, PI, PD control modes. The
dual control outputs can be configured for a variety of control and alarm
applications such as heat, heat/cool, heat/alarm, cool or cool/alarm. The ramp to
setpoint feature allows the user to define the rate of rise to setpoint, minimizing
thermal shock to the load during start-up. Maximum ramp time 99.59 (HH.MM),
Soak: 00.00 to 99.59 (HH.MM),Damping: 1 to 8 in unit steps. Input types
J,K,T,E,R,S,B,N,J-DIN¡C, RTD 100½ 0.00385, 100½ & 1k½ 0.00392, 0 to 20 mA,
4 to 20 mA, 0 to 100mV, 0 to 1V, 0 to 10Vdc. Alarm 1 output includes SPST relay,
3A @ 120Vac, 3A @ 240Vac.
NOTE: The Controller must be ordered completely configured. Options are not field installable.
[ ]
CASE TYPE
R3
NEMA 1, 1.89 x1.89" (48 x 48mm) bezel and 1.75" ROUND cutout
R5
NEMA 1, 2.1 x 2.1" bezel and 1.75Ó ROUND cutout
3
NEMA 12 bezel for
5
NEMA 4 bezel for
[ ]
CONTROL OUTPUT #1 (Direct or Reverse Acting)
2
Solid State Relay SSR : 1A @ 120/240Vac continuous
3
Relay: Form ÒCÓ 5A @ 120Vac, 3A @ 240Vac
4
Pulsed 10Vdc @20mA (for use with external SSR)
5
Non-Isolated 1 to 10Vdc or 0-20mA @500½ max
[ ]
CONTROL OUTPUT #2 (Direct or Reverse Acting)
0
Insert Ò0Ó if second output is not desired
2
Solid State Relay SSR: 1A @ 120/240Vac continuous
3
Relay: Form ÒCÓ 5A @ 120Vac, 3A @ 240Vac
4
Pulsed 10Vdc @20mA (use for external SSR)
Ordering Examples:
1.) CN77R322-C2 is a NEMA 1 bezel case with 1.75 inch round hole mounting adaptor, dual SSR control outputs and RS232 communications output.
2.) CN77330 is a NEMA 12 bezel case with 1/16 DIN mounting and single Relay control output.
3.) CN77544-A2 is a NEMA 4 bezel case with 1/16 DIN mounting, dual pulse control outputs, and a SPST 3A Alarm relay.
1
/
DIN panel cutout 45mm x 45mm (1.772 x 1.772")
16
/
DIN panel cutout 45mm x 45mm (1.772 x 1.772")
1
16
Model No. Description cont.
[ ]
OPTIONAL OUTPUTS
none (no entry required)
*
-A2
SPST relay, 3A@ 120Vac, 3A @ 240Vac (Alarm 2)
-C2
Isolated RS232, 300 to 19.2k baud
-C4
Isolated RS485, 300 to 19.2k baud
-PV
Isolated Analog Output
-RSP
Remote Setpoint Selection
[ ]
POWER SUPPLY
90 to 240 Vac/dc, 50 to 400Hz (no entry required)
*
NEMA 1/UL Type 1: Intended for indoor use, to provide a degree of
protection against contact with the enclosed equiptment and against
limited amount of falling dirt.
NEMA 4/UL Type 4: Intended for indoor use, to provide a degree of
protection against splashing water, windblown dust and rain, and hose
directed water and undamaged by the formulation of ice on the enclosure.
Testing-Hosedown: Enclosure is subjected to a stream of water from a
hose which has a 1" diameter nozzle and which delivers at least 65 gallons
per minute from a distance of 10 to 12 feet for a minimum of 5 minutes.
NEMA 12/UL Type 12: Intended for indoor use, to provide a degree of
protection against circulating dust, falling dirt, and dripping non-corrosive
liquids. Testing-Drip: Enclosure is subjected to a drip pan which produces
both splashing and dripping.
Testing-Atomized Water: Enclosure is
subjected to a spray of atomized water by using a nozzle that produces a
3" round diameter spray, 12" from enclosure. The air pressure is at 30psi.
For harsh environments, we recommend installation of the controller for
square panel cutouts.