13. Lamp House & Lamp replacement
5
Image 13-31
9. Secure the xenon lamp cathode with the hexagon socket head cap screw (reference 1 image 13-32), spring washer (reference
2 image 13-32 and plain washer (reference 3 image 13-32). Fasten the screw with a torque of 2.5Nm (1.84 lbf*ft). Use a torque
wrench with a 5 mm Allen socket.
Caution:
Make sure that both pins (reference 11 image 13-32) of the cathode adapter remain engaged in the foreseen slots.
Image 13-32
10.Install the side cover of the Lamp House and fasten the two quarter turn screws (reference 4 image 13-33) of the cover.
Note: Ensure that the quarter turn screws turning wires are flush with the cover or interference will occur while inserting the
Lamp House into the projector.
Image 13-33
116
3
2
1
11
4
2.5 Nm
2.5 .5
.5 Nm
R5905961 ZEUS 09/03/2015