Host I/O Card - Fujitsu IRF-1S series User Manual

Imageraid series
Table of Contents

Advertisement

The jumper, (JP3), must be set to one pin only or offset. This configures the bus
to single bus mode.
The jumpers JP1 and JP2 must be installed on both pins. They provide hardware
failure detect signals.
NOTE:
The Disk I/O cards are universal and can be interchanged.

Host I/O Card

The Host I/O card provides the fibre connectivity from the host computer(s) to
the Fibre Channel controller ports. This hot swappable card is designed to
support NCITS T11 Fibre Channel compliant devices at speeds of 1.0625 Gb per
sec or 2.125 Gb per sec. Each card has two SFP cages that house optical or
copper SFP transceivers. They are labeled "H0" and "H1."
The Host I/O cards are installed at the rear of the enclosure, above the controller
slots. The right Host I/O card provides connectivity to controller's port 0 (C0P0 and
C1P0) of both controllers, and the left card provides connectivity to controller's
port 1 (C0P1 and C1P1) of both controllers.
LEDs on the card's face plate will illuminate to indicate 2 Gb speed mode, host
link status, and activity.
FC Host Ports
Link Status LED
2 Gb/1 Gb Mode LED
Switch Settings
Switch
Name
1
HOST SPEED
1G/2G
2
CTRL MODE
DIS/ENA
3
HUB FAILOVER
DIS/ENA
4
HOST H0H1 LINK
DIS/ENA
5
CTRL0 P0P1 LINK
DIS/ENA
6
DUAL ACTIVE
DIS/ENA
7
GND/VCC
8
GND/VCC
Host I/O Card
Chapter 1 - Getting Started
Function
UP (ON)
DOWN (OFF)
2 Gb
1 Gb
imageRAID
Not Used
Enabled
Disabled
Enabled
Disabled
Not Used
Not Used
Enabled
Disabled
Not Used
Not Used
Not Used
Not Used
Host I/O Card
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irf-2d seriesIrf-2s seriesIrf-1d series

Table of Contents