Simplex Mode (imageRAID IRF-1Sxx-xx/IRF-1Dxx-xx)
The basic simplex (Stand-Alone) operating mode provides a single enclosure
with a single RAID Controller solution. This mode provides solutions for single or
multiple host environments to achieve a fault-tolerant disk storage solution. It has
provisions for drive channel expansion through daisy-chaining of IRF-JBOD
enclosures, and/or upgrading to a imageRAID IRF-2Dxx-xx model by adding an
additional controller for duplex operations.
CAUTION:
The bus speed must be set to the same setting between the disk
drives and the Disk I/O card(s), and the host system HBAs (BIOS
setting) and the Host I/O cards. For example, if you are using 2 Gb
drives, the Disk I/O cards must be set to 2 Gb mode. If your host
system HBA(s) is set to 1 Gb mode, the Host I/O card(s) must be set
to 1 Gb mode.
NOTE:
Split-bus mode is not supported when a RAID Controller is installed.
Stand-Alone Dual Port Single Host Configuration
1
Set the jumper (JP4) on the Disk I/O card to configure the bus speed mode.
Loosen the two captive fastener screws on the Disk I/O card and pull it from
the enclosure using the fastener screws. Locate the jumper JP4 and position it
for the desired speed setting, (installed on one pin only for 2 Gb mode and
on both pins for 1 Gb mode).
FC-AL Loop Port
Loop Status LED
2 Gb/1 Gb Mode LED
Chapter 3 - Setup and Installation
Jumper JP4 must be set
to one pin only for 2Gb mode.
Position it on both pins for
1Gb mode.
Jumpers JP1 and JP2
must be installed on
both pins .
Disk I/O Card
Simplex Mode (imageRAID IRF-1Sxx-xx/IRF-1Dxx-xx)
Jumper JP3 must be offset
or installed on one pin only.
This enables Single Bus mode.