1MRS755537
Table 5.1.14.1.-14 Fault record
Address
Signal name
601
Latest selection code
602
Sequence number
603
Unread records left
604
Time stamp of the recorded data, date
605
Time stamp of the recorded data, time
606
Time stamp of the recorded data, date and time
607
Time stamp of the recorded data, time
608
Phase current I
609
Phase current I
610
Phase current I
611
Ground-fault current
612
NPS current
613
Thermal stress value
614
Number of motor start ups
615
Thermal level at start
616
Thermal level at end
617
Temperature from RTD1
618
Temperature from RTD2
619
Temperature from RTD3
620
Temperature from RTD4
621
Temperature from RTD5
622
Temperature from RTD6
623
Thermistor 1, resistance value
624
Thermistor 2, resistance value
625
Pickup duration of element 49/38-1, alarm
626
Pickup duration of element 49/38-1, trip
627
Pickup duration of element 49/38-2, alarm
628
Pickup duration of element 49/38-2, trip
629
Pickup duration, element (48/14 PICKUP)
TDLY) or 48/14
630
Pickup duration, element 50P-1
631
Pickup duration, element 46
632
Pickup duration, element 51N
633
Pickup duration, element 37
a)
Readable and writeable register.
b)
If the input is out of operation or the optional RTD module has not been installed, the value -32768 will be returned.
c)
If the input is out of operation or the optional RTD module has not been installed, the value 655 will be returned.
Motor Protection Relay
Technical Reference Manual - ANSI Version
a)
a
b
c
Structure 3
This structure contains Modbus event records. Refer to Event records earlier in this
section for the reading method.
Range
1...2
1...999
0...6
0...999
0...5000
0...5000
0...5000
0...8000
0...5000
0...100
0...999
0...106
0...106
-40...999
-40...999
-40...999
-40...999
-40...999
-40...999
0...200
0...200
0...100
0...100
0...100
0...100
2
x (48/14
0...100
0...100
0...100
0...100
0...100
REM 610
REM 610
Comment
1 = read oldest unread record
2 = read oldest stored record
2 bytes: YY.MM
2 bytes: DD.HH
2 bytes: MM.SS
0...999 ms
0...50 x FLA
0...50 x FLA
0...50 x FLA
0...800.0%
0...50 x FLA
0...100%
0...999
0...106%
0...106%
b)
-40...999°C
b)
-40...999°C
b)
-40...999°C
b)
-40...999°C
b)
-40...999°C
b)
-40...999°C
c)
0...20 kΩ
c)
0...20 kΩ
0...100%
0...100%
0...100%
0...100%
0...100%
0...100%
0...100%
0...100%
0...100%
87