5700 ATEX Installation Instructions
EB-20025742 Rev. AC
3)
Parameters (continued)
3.3.1.1
for type 5700*1*E******(J3,terminals 1-2 FF) for the
connection of a FIELDBUS circuit in accordance with FISCO
model, Annex G of EN 60079-11:2012
voltage
current
power
effective internal inductance
effective internal capacitance
3.3.2
for type 5700*1*E******(J3,terminals 3-4, mA)
voltage
current
power
effective internal inductance
effective internal capacitance
3.3.3
for type 5700*1*E******(J3,terminals 5-6, FO/DO)
voltage
current
power
effective internal inductance
effective internal capacitance
3.4
Sensor circuits for type 5700R1******** (J1 in J-box,
VDC+ RED; VDC- BLK; COM A WHT; COM B GRN); "ib"
voltage
current; instantaneous
current; steady state
power
type of protection Ex ib IIC
max. external inductance
max. external capacitance
max. induct/resistance ratio
type of protection Ex ib IIB and IIIC
max. external inductance
max. external capacitance
max. induct/resistance ratio
Ui
DC
Ii
Pi
Li
Ci
Ui
DC
Ii
Pi
Li
Ci
Ui
DC
Ii
Pi
Li
Ci
11,27
Uo
DC
Io
0,479
Io
0,272
Po
Lo
154,9
Co
Lo/Ro
17,26
Lo
619,8
Co
Lo/Ro
December 2015
33
V
380
mA
5,32
W
5
μH
0,27
nF
30
V
484
mA
2,05
W
5
μH
0,27
nF
30
V
484
mA
2,05
W
5
μH
nF
17,2
V
A
A
2,06
W
H
333
nF
H/
H
2,04
μF
H/
69,0
6 of 12