3.1
Mains circuits:
3.1.1
for type 5700*1*(A,E,N)******
voltage
max. voltage
3.1.2
for type 5700*1*C******
voltage
max. voltage
3.2
Non intrinsically safe input/output circuits:
3.2.1
For all types(J2, USB)
voltage
3.2.2
for type 5700*1*A******(J3,terminals 1-10)
voltage
3.2.3
for type 5700*1*N******(J3,terminals 1-2, FF)
voltage
3.2.4
for type 5700*1*N******(J3,terminals 3-4, mA)
voltage
3.2.5
for type 5700*1*N******(J3,terminals 5-6, FO/DO)
voltage
3.2.6
for type 5700*1*C******(J5,terminals 1-2)
voltage
3.2.7
for type 5700*1*C******(J7/J8,ETHERNET RJ-45)
voltage
3.3
Intrinsically safe circuits "ic":
3.3.1
for type 5700*1*E******(J3,terminals 1-2 FF)
voltage
current
power
effective internal inductance
effective internal capacitance
5 of 12
5700 ATEX Installation Instructions
(J1, terminal 1 - 2)
AC/DC
Um
AC/DC
(J6, terminal 1 - 2)
AC/DC
Um
AC/DC
Um
AC/DC
Um
AC/DC
Um
DC
Um
DC
Um
DC
Um
AC/DC
Un
DC
Ui
DC
Ii
Pi
Li
Ci
EB-20025742 Rev. AC
18 - 240 V + 10 %
265
V
18 - 240 V + 10 %
265
V
10
V
30
V
33
V
30
V
30
V
30
V
2,4
V
30
V
300
mA
1,3
W
5
μH
0,27
nF