Power On / Off; Starting; Warming Up; Loading - Atlas Copco XAMS 407 CD Instruction Manual

Portable compressors. engine cat c7
Table of Contents

Advertisement

POWER ON / OFF

(ON/OFF)
(2)
(3)
Switch on the battery switch
Switch the machine on by switching the "ON/OFF"
switch to the position "ON".
The display will show:
25.5V
00007.7 h
With the scroll buttons (1) you can scroll through the
display information

STARTING

Press the button "I" (2)
• When the ambient temperature is below
10°C ( 50°F) the display will show:
Fuel
00000.h
Indicating that preheating is necessary before the
engine will start.
• When the ambient temperature is over
10°C ( 50°F) the display will show:
00007.7 h
(1)
12%
25.5V
22°C
- 40 -

WARMING UP

When the engine started the warming up is started.
The compressor can be loaded after the compressor
has reached a temperature of 40°C, or after a warming
up period of 5 minutes.
After warming up the LED at the load button will
blink at low frequency, the engine will run idle.
When pressing the load button (3) the display will
show:
25.5V
00007.7 h
and the compressor will be loaded after warming up

LOADING

By pressing the load button (3) the compressor will be
loaded, the pressure will rise until it reaches the
setting. The LED at the load button will blink at high
frequency and will be lit continuously when the set
pressure is reached.
The display will show:
28.9V
00007.7 h
With the scroll buttons (1) you can scroll through the
display information

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents