Page 2
Please accept our apologies in this eventuality. An updated version can be requested from the BORA Service Team. Subject to printing errors and mistakes.
Airflow to left (installation rotated around 180°) ..... 23 and spare parts Installing the duct system ......... 24 11.1 Warranty ............42 6.8.1 Preparing for installation ........24 11.2 Service .............. 42 6.8.2 Connect the duct system to the device....25 www.bora.com...
& Co KG, BORA APAC Pty Ltd and BORA Lüftungstechnik GmbH - hereinafter referred Target group to as BORA - do not assume any liability for damage arising from non-adherence to these These operating and installation instructions apply for the...
Page 5
Caution Indicates a potentially hazardous situation which could lead to slight or minor injuries if ignored. — Caution Indicates a situation which could result in material damage if ignored. Tab. 1.2 Meaning of warning symbols and signal words www.bora.com...
Avoid boiling over. appliance. Only operate the cooktop extractor with Cleaning and maintenance BORA cooktops. This particularly applies to use with BORA gas cooktops. The device must be cleaned regularly. Dirt Switch the device off after use. can lead to damage or the buildup of odours.
While the cooktop extractor is (pot holders, oven gloves). working, it sucks up grease from cooking. Flambéing food can cause the grease to catch fire. Clean the cooktop extractor regularly. Never work with a naked flame while the cooktop extractor is running. www.bora.com...
Ensure that the stated stripping lengths are adhered to. Check the appliance for visible damage before installing it. Do not install damaged devices. A damaged device is a hazard. Repair work must only be carried out by specialists authorised by the manufacturer. www.bora.com...
Securely disconnect the appliance use that goes beyond that which is described from the mains using LS switches, here is classed as unintended. BORA does not fuses, automatic circuit breakers assume any liability for damages caused by or contactors.
50/60 Hz Power consumption (including external max. 700 W Fig. 3.2 PKA Device dimensions front view BORA universal article fans) Dimensions (width x depth x height) 482 x 540 x 176 mm Dimension of control knob Ø 49 mm (diameter x depth) Ø...
220 - 240 V Frequency 50/60 Hz Power consumption (including external max. 700 W BORA universal article fans) Power consumption of internal motor max. 170 W Dimensions (width x depth x height) 468 x 540 x 199 mm Fig. 3.7...
Information on the energy consumption label in accordance with Ordinance (EU) no. 65/2014 or 66/2014. * This specification is not applicable for this product. ** The sound pressure level has been determined from a distance of 1m (distance-dependent level recording) on the basis of the sound power level established in EN 60704-2-13. www.bora.com...
(see the Cleaning and maintenance section). INFO In recirculation mode, ensure sufficient Fig. 5.2 Cooktop extractor system PKAS ventilation and aeration to expel humidity. cover frame Holding plate Control unit Fan housing with fan Control knob Cover flap www.bora.com...
Configuration menu Tab. 5.1 Meaning of display Knob operation The cooktop extractor is operated using a control knob. By twisting the control knob and pressing the touch surface, the power levels and functions are controlled (see Operation section). www.bora.com...
The grease filter sensor detects whether the grease filter is properly fitted. If the grease filter is missing or fitted incorrectly, the cooktop extractor is deactivated. INFO If the grease filter has been removed, for example for cleaning purposes, the cover flap can still be closed. www.bora.com...
(see table (see Table 6.1 and 6.2). If there are any missing or damaged parts, please The following tools are required to correctly install the notify BORA After Sales Service. cooktop extractor: Do not under any circumstances install parts which are Pencil damaged.
For cooktop extractor PKA used in conjunction with straight ducting piece PKA1FEV, flush mounting is also possible for worktop depths Fig. 6.6 Surface mounting cut-out ≥ 650 mm. 6.4.2 Flush installation A ±2 B ±2 Fig. 6.3 Flush installation www.bora.com...
Place the cooktop extractor [2] in the middle of the Cross bars on the kitchen unit in the area of the relevant worktop cut-out [1]. worktop cut-out may need to be removed. Precisely position the cooktop extractor [2]. www.bora.com...
The labels shows the cutting mark to go with the worktop thickness. If necessary, shorten the mounting clamps in line with the worktop thickness. To do this, cut the mounting clamps at the appropriate cut marks using a cutter. www.bora.com...
Push the mounting clamps [2] into the holders provided on the cooktop extractor [3] or the alternative positions on the holding plate [1]. Fig. 6.18 PKA duct connection dimensions with straight ducting piece Fig. 6.15 Tighten the mounting clamps www.bora.com...
Pre-drill the bore hole to prevent tearing out the panel. Example bore holes Fig. 6.23 Structure of control knob Knob casing Universal nut ≥70 knob ring Fig. 6.21 Bore holes for 2 cooktops, 2 sockets and 1 cooktop extractor www.bora.com...
Remove the angled ducting piece [1]. must be rotated around 180°. This means If necessary, rotate the cover frame around 180° (see the cover frame also needs to be rotated (see Rotating the cover frame around 180°). rotating the cover frame around 180°). www.bora.com...
Rotate the cooktop extractor and place it down carefully with the visible surface on a soft surface (e.g. a blanket). Carefully undo the holding clamps (18x) with a screwdriver. Fig. 6.28 Turn angled ducting piece Angled ducting piece Ducting piece adapter www.bora.com...
Preparing for installation of cooktop extractor Depending on the installation situation, adjust the levelling feet on the floor unit as necessary. Prepare the plinth fan by attaching the sealing tape depending on the installation situation. Secure the sealing tape to the inlet nozzle. www.bora.com...
176 cm², which equates to a round pipe with Pull out the seal [2] on the connection fitting [1] of the a diameter of 150 mm or the BORA Ecotube duct device. This means stretching the seal [2] slightly.
Remove the screws from the universal control unit. controlling external installations 250 VAC depending on the operating / 30 VDC, Lift up the cover [1]. status of the cooktop extractor 2,5A (cooktop extractor on: contact closed) Tab. 6.4 Switch contacts www.bora.com...
Page 27
Use the order code UFH (universal filter sleeve) to connection clamp. order the filter sleeve from your specialist supplier or Adhere to the connection diagram when connecting contact BORA via the website at www.bora.com. Home In and Home Out. www.bora.com...
[4]. Remove the relevant snap-out element [2] in the plastic housing of the universal control unit. Fig. 6.44 Back of control knob with connection Control knob connection Fig. 6.43 Home Out contacts with strain relief www.bora.com...
Control line for additional fan Use the CAT 5 communication cable to connect the Mains connection cable for additional fan connection for the control unit on the cooktop extractor Power supply cable with microfuse to the connection on the universal control unit [1]. www.bora.com...
Do not use damaged components. Tab. 6.6 Menu options in the configuration menu Contact your BORA specialist supplier to replace any damaged components. Touch the touch surface on the control knob again for 1 second to confirm the menu you want.
When you have confirmed menu option , you can select extraction system is operated with or without the the operating mode. BORA 3box (UEBF) wall sleeve. Setting Mode Setting Mode Normal operating mode...
Explain all safety-related aspects of operation and handling to the user. Affix the nameplate supplied to the back of these operating and installation instructions. Provide the user with the accessories and the operating and installation instructions for safe storage. www.bora.com...
Observe all safety and warning information during operation (see the Safety section). INFO The cooktop extractor must only be operated with BORA cooktops. INFO The cooktop extractor can only be operated if the grease filter components are installed. General operating instructions The cooktop extractor is controlled using the control knob.
The filter service display is shown every time the cooktop extractor is switched on and remains active until the filter has been changed and the filter service display has been reset. The cooktop extractor can still be operated without limitations. www.bora.com...
Twist the control knob to the 12 o’clock position. Within 10 seconds, press the touch surface of the control knob for 5 seconds. The display switches to and the filter service display is reset. Configuration menu see the Installation section www.bora.com...
Remove the cover flap, grease filter and filter tray prior to cleaning. Clean the surfaces using a soft, damp cloth, detergent Fig. 8.2 Removing the grease filter components or a mild window cleaning agent. www.bora.com...
Removing the maintenance tray Maintenance tray Locking To unlock the maintenance tray [1], twist the two locking levers [2] 90° outwards. Remove the maintenance tray [1] from the cooktop extractor. Fig. 8.4 Inserting the cover flap Exhaust opening Guided tour Cover flap www.bora.com...
Dry the touch surface and the knob housing carefully. Place the knob ring back on the knob housing. INFO If the knob ring has not been fitted correctly, a segment rotating clockwise is displayed in the central control knob display www.bora.com...
INFO You can obtain activated charcoal filters from your specialist supplier or by contacting BORA via the website at www.bora.com. A description of how to replace the activated charcoal filter can be found in its operating instructions.
After troubleshooting, turn the knob ring to the 12 o’clock position (0 position). In all other cases, contact the BORA Service Team (see section ‘Warranty, technical service and spare parts) and enter the error number displayed and the device type.
Remove the device from the worktop by lifting it components and other materials. upwards. Remove any other accessories. Dispose of the old device and any contaminated accessories as described under “ Environmentally- friendly disposal”. www.bora.com...
BORA specialist supplier or the BORA Service Team. The BORA Service Team requires the type designation and the build number of your appliance (FD number). Both pieces of information can be found on the nameplate on the back of the instructions and on the appliance base.
Page 44
F +49 (0) 8035 / 907-249 F +61 2 8076 3514 info@bora.com info@boraapac.com.au www.bora.com www.boraapac.com.au Austria: BORA Vertriebs GmbH & Co KG Prof.-Dr.-Anton-Kathrein-Straße 3 6342 Niederndorf Austria T +43 (0) 5373 / 62250-0 F +43 (0) 5373 / 62250-90 mail@bora.com www.bora.com...
Need help?
Do you have a question about the PKA1UMEN-001 and is the answer not in the manual?
Questions and answers