Selecting The Operating Mode - DeDietrich AWHP-2 MIT-IN-2 iSystem User Manual

Air / water heat pump
Hide thumbs Also See for AWHP-2 MIT-IN-2 iSystem:
Table of Contents

Advertisement

AWHP-2 MIT-IN-2 iSystem
C Menu
Parameter
(2)
WATER T.NIGHT
(2)
TEMP.TANK AUX
(2)
WATER T.NIGHTAUX
(2)
DHW A TEMP.
(2)
WATER T.NIGHT.A
(2)
TEMP.SOL.TANK
(2)
SWIMMING P.T.B
(2)
SWIMMING P.T.C
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
MODE Menu
Parameter
Adjustment range Description
AUTOMATIQUE
7/7, xx:xx
DAY
7/7, xx:xx
NIGHT
7/7, 1 to 365
HOLIDAYS
SUMMER
(1) The start and end days and the number of days are calculated in relation to each other.
(2) The parameter is only displayed if a room sensor is connected.
10/06/2015 - 7616372-001-05
Adjustment range Description
Set tank temperature, night programme
10 to 80 °C
Desired domestic hot water temperature in the auxiliary
10 to 80 °C
circuit
Desired domestic hot water temperature in the auxiliary
10 to 80 °C
circuit for the night program
10 to 80 °C
Desired domestic hot water temperature in circuit A
Desired domestic hot water temperature in the tank
10 to 80 °C
connected to circuit A for the night program
10 to 80 °C
Temperature of the hot water produced by solar power (TS) 55 °C
0 to 39 °C
Desired temperature for swimming pool B
0 to 39 °C
Desired temperature for swimming pool C
5.3.2.
To select an operating mode, proceed as follows:
1. Press the MODE key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
MODE
C002267-A
The comfort ranges are determined by the timer programme.
Comfort mode is forced until the time indicated or all the time (7/7). Present time + 1
Reduced mode is forced until the time indicated or all the time
(7/7).
The antifreeze mode is active on all boiler circuits.
Number of days' holiday: xx
heating OFF: xx:xx
Restarting: xx:xx
The heating is off.
Domestic hot water continues to be produced.

Selecting the operating mode

To go back to the previous display, press the key j .
To cancel, press key h .
(1)
(1)
(1)
5. Operating the appliance
Factory setting
10 °C
55 °C
10 °C
55 °C
10 °C
20 °C
20 °C
Factory setting
hour
Present time + 1
hour
Present date + 1
day
26