Freeze Protect Temperature? Select the temperature to be used for freeze protection.
Temperature is adjustable from 33ºF-42ºF (1ºC-6ºC). 38ºF (3ºC) is default. This threshold
will be used for all outputs that have freeze protection enabled.
Freeze Protect Speed? For two speed pumps only, select 50% or 100%.
If VSP is selected:
Which Hayward Unique Address? If using a VSP, you'll be asked what is the Hayward
Unique Address (HUA). If a value is already shown in the box, advance to the next screen.
If no value is shown, selecting the box will bring you to a table showing all detected de-
vices. Select the proper HUA from the table and touch the Done button. If unsure of the
HUA, refer to the pump's manual for instructions on how to determine the pump's HUA.
Once selected, the address should now be shown in the box and you can advance to the
next screen to continue the VSP configuration.
Pump Capacity - Set the minimum and maximum RPM of the pump. Refer to your pump
manual for more information.
Permitted User Setting - The VS Omni will automatically calculate these values based
on the minimum and maximum RPM that were previously entered. They can be changed
as desired.
Speed Presets - Set the Low Pump Speed %, Medium Pump Speed %, and High Pump
Speed %, presets. These presets will be used when setting schedules for your pump.
Filter Pump Off for Valve Change? When Yes is selected, the pump will shut off for 35
seconds whenever the valve(s) change position.
Flow Monitoring Enabled? Requires use of a Hayward flow switch. This feature will help
protect the filter pump from damage due to no flow. When Yes is selected, the VS Omni
will monitor the state of water flow when the filter pump is on. If no flow is detected for
more than 15 minutes, the VS Omni will shut down the pool pump and will indicate an
error. The error will be cleared the next time the pump is turned on.
Would You Like to Enable Priming? Select whether you want the filter pump to prime
when turned on. This will turn the pump on at high speed for a set duration to establish
normal water flow every time the pump is activated after being off for at least 30 seconds.
NOTE: this option only appears if the pump is a two speed pump or a variable speed pump.
If Yes is selected:
Enter Priming Duration: This is the number of minutes that the pump will prime
before returning to the scheduled speed. Select 0-15 minutes.
Freeze Protection Enabled? Freeze protection is used to protect the pool and plumbed
equipment against freeze damage during cold temperatures. If freeze protection is en-
abled AND the air temperature falls below the freeze threshold, the VS Omni will turn on
the filter pump to circulate the water.
If Yes is selected:
29
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS