Table B-6. M&C Signal Description (Connector J5 - Comtech EF Data CSAT-5060 Installation And Operation Manual

100 watt c-band transceiver
Table of Contents

Advertisement

100Watt C-Band Transceiver
Redundant Systems
Pin
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
B.2.1.6 T
IF I
X
NTERFACES
The Tx IF input signal is fed from the customers equipment to the RSU-5060 at connector J6.
The RSU-5060 contains a power splitter which feeds the IF input signal to both CSAT A and
CSAT B via the J7 and J8 connectors. The IF power at J7 and J8 will nominally be 3dBm less
than the IF input power at J6.
Table B-6. M&C Signal Description (Connector J5)
Signal Name
Type
RS485 RX+
Pass-thru
RS485 RX-
Pass-thru
RS485 TX+
Pass-thru
RS485 TX-
Pass-thru
B ONLINE CLOSED
Output
n.c.
n.c.
n.c.
n.c.
IND/FLT COMMON
Input
A FAULT OPEN
Output
B FAULT OPEN
Output
n.c.
RED AUTO/MAN
Input
n.c.
A ONLINE CLOSED
Output
GROUND
Passive
GROUND
Passive
SWITCH CMD
Input
, J6, J7,
Description
RS-485 Rx+, From M&C to CSAT A&B
RS-485 Rx-, From M&C to CSAT A&B
RS-485 Tx+, To M&C from CSAT A&B
RS-485 Tx-, To M&C from CSAT A&B
Shorted to pin K = CSAT B Online
Shorted to pin K = CSAT A Faulted
Shorted to pin K = CSAT B Faulted
Ground = Manual, Open = Auto
Shorted to pin K = CSAT A Online
Momentary short to GND, otherwise OPEN
J8
AND
B-5
Revision 0
MN/CSAT5060100.IOM