Comtech EF Data CSAT-5060 Installation And Operation Manual page 25

100 watt c-band transceiver
Table of Contents

Advertisement

CSAT-5060
Transmit
Frequency, RF
Frequency IF
Output Power, P
1Db
Gain
Attenuator Range
Gain Flatness
Gain Stability
Carrier Mute
Intermodulation
Second Harmonic
Spurious
All other in-band
AM to PM Conversion
RF Output VSWR
RF Output Connector
IF Input Impedance
IF Input VSWR
IF Input Connector
Receive
Frequency RF
Frequency IF
Gain, without LNA
Gain Flatness, without LNA
Gain Stability, w/o LNA
Output Power, P1dB
Two Tone Inter-modulation
Image Rejection
RF Input VSWR
RF Input Connector
IF Output Impedance
IF Output VSWR
IF Output Connector
5845 to 6425 MHz
6425 to 6725 MHz (Optional Extended)
5850 to 6650 MHz (Optional Wide)
5845 to 6725 MHz (Optional Super Wide)
70 MHz ± 18 MHz
140 MHz ± 36 MHz (Optional)
(50W)
+47 dBm
(100W)
+50 dBm
(50W)
74 dB
(100W)
77 dB
25 dB in 0.25 dB steps
± 0.75 dB full RF band
± 0.75 dB per 36 MHz
± 0.25 dB at constant C
± 1.00dB from -40° to+55°C (-40 to 131° F)
-70 dBc
-33 dBc for two carriers at 6 dB OPBO from
rated power
-55 dBc
AC line harmonics
-45 dBc
Carrier related, <500kHz
-60 dBc
(50 W) -18 dBm
-65 dBc
(100 W) -15 dBm
-65 dBc
3.0° at 6 dB OPBO from rated power
1.25:1
CPR137G
50 Ohms
1.25:1
Type N Female
3625 to 4200 MHz
3400 to 4200 MHz (Optional)
70 MHz ±18 MHz
140 MHz ± 36 MHz (Optional)
45 dB
± 0.75 dB full RF band
± 0.75 dB per 36 MHz
± 0.25 dB constant temp.
± 1.00 dB -40° to +55°C
+13dBm
-50 dBc for two tones at 0 dBm each, 1 MHz
apart
-60 dBc
1.25:1
Type N Female
50 Ohms
1.25:1
Type N Female
C-Band Transceiver
50 and 100 Watt
Common
Conversion
Dual, no spectral inversion
Frequency Step Size
1.0 and 2.5 MHz automatic
Frequency Stability
1x10
1x10
-40° to +55°C
Attenuation
TX
RX
Phase Noise
100 Hz
1 kHz
10 kHz
100 kHz
Group Delay
Linear
Parabolic
Ripple
Monitor and Control
Methods
Both EIA-485 and EIA-232 Serial Interface
Handheld controller, optional
Commands
Set TX frequency
Set RX frequency
Set TX attenuation
Set RX attenuation
Report TX output power
Mute TX
Report internal temperature
Report power supply voltages
Set time
Set date
Faults
Upconverter functions
Downconverter functions
Upconverter Synthesizers
Downconverter Synthesizers
Internal Reference oscillator
LNA current fault
Over temperature condition
Environmental
Temperature
-40° to +55° C (-40 to 122° F) Operating
-50° to +75° C (-90 to 135° F) Storage
Altitude
15,000 ft, mean sea level
Humidity
0 to 100 Percent, Relative
Prime Power
90 to 260 VAC Standard
47 to 63 Hz Standard
48 VDC Optional
RF Power
Steady State True AC Power Requirement (110 VAC)
50W
410W
100W
750W
Dimensions:
50 W
100 W
Weight:
50 W
100 W
Low Noise Amplifier
Comtech EF Data reserves the right to make changes to specifications of products described in this
data sheet at any time without notice and without obligation to notify any person of such changes.
© 2001 Comtech EFData (Part Number DS/CHP1.DOC)
/day
-9
/year
-7
1x10
/Temp
-8
0-25 dB in 0.25 dB steps
0-20 dB in 0.25 dB steps
-66 dBc/Hz
-76 dBc/Hz
-86 dBc/Hz
-96 dBc/Hz
0.1 ns/MHz
0.02 ns/MHz
2
1 ns p-p
9.75H x 10W x 23D inch
(24.77H x 25.4W x 58.42D cm)
10 H x 12.5W x 26D inch
(25.4H x 31.75W x 66.04D cm)
65 lbs (29 kg)
80 lbs (40 kg)
45° K, non-isolated
6/6/02

Advertisement

Table of Contents
loading

Table of Contents