Risk of injury!
Hot water
splashes can escape
during the leakage
test. Wear safety
glasses for the
inspection.
80
F I N A L T E S T S
3. Place coffee machine on a heat
resistant, electrical insulating
surface.
4. Secure coffee machine against tilting
with case of bottom part.
8. Plug in coffee machine.
9. When machine is ready, set bar
display to level 7 with selector wheel.
10. Push selection lever to right position
"HOT". Machine starts rinsing.
Lumio service manual
5. Insert capsule holder with dummy
capsule and test device  p. 72.
6. Insert water tank.
7. Place an appropriate container under
test device.
11. Close pressure control valve progres-
sively to reach Pmax (11.5 - 14.5 bar
if possible).
12. Turn selection lever to middle posi-
tion "STOP"
13. Unplug coffee machine.
STOP