Use a flathead
screwdriver for easy
removal.
Use flat nose pliers
for easy removal.
46
R E P A I R
8
20
3. Pull both rubber supports (part of pump 19) out of the guides in component frame
(8) alternately.
4. Unplug flat receptacle with brown wire from pump terminal.
This flat receptacle has a special connector latching.
Press down lever with flat nose pliers when pulling recep-
tacle.
Lumio service manual