Check
procedure
11.1 Check vibrations while
11 Check for loud
putting a plastic beaker on
noises or vibra-
the drip grid. Plastic beaker is
tions
moving around?
12.1 When disposing the
12 Checks after
used capsule: capsule does
preparing a
not fall out of the capsule
beverage
holder?
13 Perform
remaining final
tests ( p. 70) and
clean machine
No trouble found during the check procedure?
Contact the sales partner in your local region as per the Instruction book and warranty card.
Symptoms
YES - a) Drip tray and drip grid
are inserted correctly
YES - b) Rubber straps of pump
are defective or not assembled
correctly
YES - Check capsule or capsule
holder (3)
NO - Go to point 13
End of check procedure.
T R O U B L E S H O O T I N G
Action / repair work
Lumio service manual
Further action /
repair work
YES - Go to point b)
NO - Assemble correctly or
replace defective part(s)
YES - Check correct
assembly. Replace pump
(19) if necessary ( p. 45)
NO - Go to point 12
YES - Clean capsule
holder, replace if necessary