Connecting To The Serial Ports - Alcatel-Lucent OA5725R Installation Manual

Table of Contents

Advertisement

Alcatel-Lucent Enterprise
ADSL installation with a micro-filter
Fig. 14:

3.5.4 Connecting to the serial ports

The OA5725R router family can have one or various female DB9 connectors.
3.5.4.1 Console connector as serial port (CONF connector)
It's possible to convert the console port into an RS-232 asynchronous DCE serial port. This port has the following
characteristics:
• DCE port.
• RS-232 norm.
• Maximum speed of 38400 bps.
• Only the following signals are available: RxD (pin 2), TxD (pin 3) and GND (5).
• DB-9 connector.
Console connector as serial port
Fig. 15:
To use this as the router's configuration port, please see section
OA5725R Router
Connecting to the router
on page 27.