Ensure that the suction system guarantees these values
A
at the hood-houth connection point. (Fig.3.5)
Suction mouth diameter:
A - Blade guard ...... ø30 mm
B - Body dust suction ...... ø100 mm
Connect the mouths to the suction system with flexible
tubes of adequate diameter. Tighten with clamps. The
tube must be positioned in such a way so as not to
obstruct the operator during machining.
WARNING
Always work with the suction system on. Always start the
B
suction system and the machine at the same time.
Fig.3.5

3.6 SAFETY DEVICES

B
The machine is equipped with the following safety
devices: (Fig.3.6)
A - Stop button.
When the button is pressed, the power is immediately cut.
A
B - Saw guard
Fig.3.6