Command And Response Table For Sis Commands - Extron electronics SW2 USB User Manual

Usb switchers, sw usb series
Hide thumbs Also See for SW2 USB:
Table of Contents

Advertisement

Command and Response Table for SIS Commands

ASCII Command
Command
(Host to Unit)
Input Selection
X!
Select input
X!
Select SW USB input
only
Hot Key
E
Enable and disable hot
key
E
View hot key status
Configure RS-232 Pass-through
E
Send SIS commands
via computer RS-232
interface
E
Send input selection
commands via contact
closure, front panel,
or the RS-232 interface
E
View loop-through
setting
Front Panel Lockout (Executive Mode)
Enable executive mode
1X
0X
Disable executive mode
Lockout status
X
Information Requests
Request information
I
N
Request part number
Query firmware version
Q
Example:
Q
*Q
Query version and build
Reset
E
Reset
Response
(Unit to Host)
!
Chn
^
Usb
X@
}
H
USBC
UsbcH
}
X@ ]
H USBC
}
1LOOP
Loop1
}
0LOOP
Loop0
}
LOOP
Loop
Exe1
Exe0
X# ]
Chn
60-95n-nn
n.nn
1.01
n.nn.nnnn
}
ZXXX
Zpx
Additional Description
X! ]
Select input
the attached AV switcher (if any).
X!
= 1, 2, 3, or 4.
X! ]
Select input
passed through).
X@ ]
Enable and disable the hot key function.
X@
For
:
1 = enabled
0 = disabled
Display current hot key status
]
Pass SIS commands through the RS-232
Pass Thru port to the AV switcher only if
the commands are sent to the SW USB via
the computer RS-232 interface.
]
Pass all SIS commands sent from the
computer RS-232 interface, and only
input selection commands sent via the
front panel or contact closure, to the AV
switcher via the RS-232 Pass Thru port.
X# ]
View pass-through setting
0 = Loop 0 mode is enabled.
1 = Loop 1 mode is enabled.
]
Lock the front panel.
]
Unlock the front panel.
Show executive mode on/off status.
X#
: 1 = on, 0 = off
For
X!
X$
X$
• InACT
• OutACT
Show the selected input and output.
X$
= Activity of all inputs and outputs
For SW USB Plus only:
X%
= Mouse emulation switch position
X^
= Keyboard emulation switch position
X%
For
and
]
Show the SW USB part number.
SW2 = 60-952-02, SW4 = 60-953-02,
SW4 USB Plus = 60-954-02.
]
Show firmware version, expressed to the
second decimal place.
]
The unit firmware version is 1.01.
]
Show firmware version and build number.
]
Reset the switcher to factory default
values.
SW USB Series • SIS Programming and Control
X!
for both the SW USB and
X!
on the SW USB only (not
X@
.
X#
X#
. For
:
X% X^ ]
• Emul
X^
: 0 = off (down); 1 = on (up)
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw4 usb plusSw4 usb

Table of Contents