3 Components and Power Supply
Power management switch
Fig. 9:

3.3.6 Deactivating Power Management

The SW100 microswitches 1 and 2, labeled as IGNITION, must be in the OFF position.

3.3.7 Activating the Power Management

The SW100 microswitches 1 and 2, labeled as IGNITION, should be in the ON position
Caution
This is a factory setting (i.e. the devices are already configured in this mode on exiting the factory).
In this operating mode, the device expects to be constantly powered and the ACC / IGNITION signal operates as a
switch. When power is applied to the device (BATTERY /VCC) the device remains switched off. It will only switch on
when the signal (+12 V or +24 V) is applied by the ignition pin (ACC / IGNITION).
Similarly, if the ignition signal deactivates once the device has switched on, the device remains switched on for the
period of time configured through the "set ignition-off-powerdown-timer <value> " command.
*
*p 4
Config>set ?
application-active
console
contact-person
data-link
default-conf
file-cfg
ftp
host-location
hostname
ignition-off-powerdown-timer
inactivity-timer
login
password
pool
schedule-restart
telnet
web-probe
Config>set ignition-off-powerdown-timer ?
<1..1440>
disabled
Config>set ignition-off-powerdown-timer 10
Config>
For further information on this command, please see manual ALU- Dm704-I Configuration and Monitoring.
12
Permits you to select the code used to boot the router
Set console configuration
Assign a name or identification to the contact-person
Type of data link for a WAN line
Restores the default configuration
Configure a configuration file as active
Permits you to access the FTP configuration menu
Physical location of the router
Assign a name to a device
Configure the time to router power down after car
ignition off
Configure the maximum inactivity time
Configure login options
Configure the device access password
Number of bytes assigned to each memory pool
Allows to configure router reset schedule
Access the TELNET protocol configuration
Access the Web probe configuration
Power down timeout in minutes
Disable ignition off power down timer
Alcatel-Lucent
OA5725A Router

Advertisement

Table of Contents
loading

Table of Contents