RED TECNIKA 28 Use And Installation Manual page 35

Table of Contents

Advertisement

red
 
CAUTION - Use of flammable liquids is not allowed. The figure shows how to arrange starter
material in the fuel hopper chamber of the boiler.
Figure 6.4.2 Arrangement of starter material needed to start the boiler combustion process.
After initial combustion, close the door to prevent combustion gases from being released from the
chamber. Combustion gases produced by the combustion process pass through the open start-up fin
and are aspirated by the chimney.
NOTE:
Starting speed may vary according to local conditions (chimney and atmospheric conditions). This
process must be observed close to acquire the practical experience needed to start the fire.
After starting the fire, turn the combustion gas fan on (turn the START switch to the ON position),
close the fuel hopper door and close the start-up fin by pushing the lever backwards. This will make
the combustion gas change direction and flow through the burner nozzle, the combustion chamber
and the convective ducting section of the boiler instead of being conveyed directly to the chimney.
Turn the combustion gas thermostat to set the operating position. The position must be determined
on a trial and error basis (you are advised to mark the position for the sake of convenience) by
observing the start-up process in the boiler.
Adjust the thermostatic valve for controlling the air flow. After start-up, the fin must be open to
ensure available air for the combustion process. After turning on the boiler and reaching operating
parameters, set the thermostatic valve as needed (
Start-up procedures
 
TECNIKA 28-35
USE AND INSTALLATION MANUAL
see description below
).
Technical dept. - All rights reserved - Reproduction prohibited