Dimensions and technical data of "TECNIKA" hot water wood gasification boilers:
PARAMETERS
WEIGHT
WATER SLEEVE CAPACITY
FUEL CHAMBER CAPACITY
NOMINAL HEAT OUTPUT TIME INTERVAL AFTER LOADING
FUEL CHAMBER
MAXIMUM WOOD LOG LENGTH
DIMENSIONS
OPERATING PRESSURE OF CIRCULATING WATER
HYDRAULIC PRESSURE LOSS AT NOMINAL HEAT OUTPUT
TYPE OF EXPANSION VESSEL FOR THE HEATING SYSTEM
PRESSURE TESTED IN THE FACTORY
RECOMMENDED TEMPERATURE FOR THE WATER
CIRCULATING IN THE BOILER
RECOMMENDED TEMPERATURE FOR RETURN WATER IN THE
BOILER
DRAUGHT
CONNECTIONS
POWER SUPPLY
POWER SUPPLY CABLE
ELECTRICAL CAPACITY
ELECTRICAL PROTECTION
BOILER CLASS (ACCORDING TO EN 303-5)
 
Technical specifications and dimensions
 
USE AND INSTALLATION MANUAL
MODEL
L=WIDTH
P=DEPTH
A=HEIGHT
FLOW/RETURN
EXHAUST
EMERGENCY COOLING COIL
COMBUSTION GAS DUCT
TECNIKA 28-35
UNIT OF MEASURE
Hours
Technical dept. - All rights reserved - Reproduction prohibited
28
290
kg
70
3
dm
100
3
dm
16-20
kg
2-3
330
mm
975
mm
bar
Pa
20
-
Open or closed
bar
°C
°C
hPa
G
G
G
mm
230 V; 50 Hz
-
3 x 1.5 mm
-
VA
37
-
-
Chapter
3
page 10
VALUES
35
370
90
130
20-24
2-3
500
780
1123
1282
2
21
4
80-85
60
0.18-0.24
1 ½"
¾"
½"
150
2
65
IP20
3