Step 2.5 Loading the Standalone Diagnostics from CD-ROM

To run standalone diagnostics in service mode from CD-ROM, do the following:
1. Stop all programs including the AIX operating system (get help if needed).
2. Remove all tapes, diskettes, and CD-ROMs.
3. Power off the managed system (refer to Full System Management Tasks in the
Hardware Management Console for pSeries Operations Guide ).
4. Use the HMC to power on the managed system in full system partition mode. Select
the Power on Diagnostic Stored Boot List option (refer to Full System
Management Tasks in the Hardware Management Console for pSeries Operations
Guide ).
5. Insert the diagnostic media into the CD-ROM drive of the Eserver pSeries 670 ( not
into the HMC CD-ROM drive).
6. Enter any requested passwords.
Go to "Step 3. Running System Verification".

Step 3. Running System Verification

When the Diagnostic Operating Instructions display, do the following to run system
verification:
1. Press Enter.
2. If the terminal type is requested, you must use the Initialize Terminal option on the
Function Selection menu to initialize the operating system before you can continue
with the diagnostics. Select VT100 terminal emulation.
3. Select the System Verification option on the Diagnostic Mode Selection menu.
4. To run a general checkout of all installed resources, select the All Resource option
on the Diagnostic Selection menu. Follow the instructions on the screen to complete
the checkout procedure.
To check one particular resource, select that resource on the Diagnostic Selection
menu.
The checkout program ends with either of the following results:
v The Testing Complete screen displays a message stating No trouble was found.
v The A Problem Was Detected On (Time Stamp) menu displays, with either a service
request number (SRN) or an error code. Make a note of any codes displayed on the
display or operator panel.
To perform additional system verification, go to "Step 4. Performing Additional System
Verification" on page 119. To exit diagnostics, go to "Step 5. Stopping the Diagnostics"
on page 119.
Eserver pSeries 670 User's Guide