Front Panel Lcd Messages; Lcd Module And Server Status Information - Dell EMC PowerEdge VRTX User Manual

Chassis management controller
Table of Contents

Advertisement

server's System Event Log (SEL). For chassis errors, use the CMC web interface or command line interface to clear the hardware
log.

Front Panel LCD Messages

This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event Log (SEL) viewed from the CLI or Web interface.
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and the possible
cause of the message. Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this section describe
the information that is displayed for each component.

LCD Module and Server Status Information

The tables in this section describe status items that are displayed on the front panel LCD for each type of component in the chassis.
Table 44. CMC Status
Item
Name/Location
No Errors
Firmware Version
IP4 <enabled, disabled>
IP4 Address: <address, acquiring>
IP6 <enabled, disabled>
IP6 Local Address: <address>
MAC: <address>
Table 45. Chassis or Enclosure Status
Item
User Define Name
Error Messages
Model Number
Power Consumption
Peak Power
Minimum Power
Ambient Temperature
Service Tag
CMC redundancy mode
PSU redundancy mode
Description
Example: CMC1, CMC2.
If there are no errors, No Errors is displayed. Else, error messages are listed
where critical ones are first listed, and then the warning-related.
Only displays on an active CMC. Displays Standby for the standby CMC.
Displays current IPv4 enabled state only on an active CMC.
Only displays if IPv4 is enabled only on an active CMC.
Displays current IPv6 enabled state only on an active CMC.
Only displays if IPv6 is enabled only on an active CMC.
Displays the CMC's MAC address.
Description
Example: "Dell Rack System". This can be configured using the CMC CLI or Web interface.
If there are no errors, No Errors is displayed. Else, error messages are listed where critical ones are
first listed, and then the warning-related.
Example "PowerEdgeM1000".
Current power consumption in watts.
Peak power consumed in watts.
Minimum power consumed in watts.
Current ambient temperature in degrees Celsius.
The factory-assigned service tag.
Non-Redundant or Redundant.
Non-Redundant, Grid Redundant, or DC Redundant.
201