Dell EMC PowerEdge VRTX User Manual page 113

Chassis management controller
Table of Contents

Advertisement

Privilege
User Configuration
Administrator
Clear Logs
Administrator
Chassis Control
Administrator (Power
Commands)
Server Administrator
Description
User can:
Add a new user.
Change the password of a user.
Change the privileges of a user.
Enable or disable the login privilege of a user but retain the name and other privileges of the user in
the database.
User can clear the hardware log and CMC log.
CMC users with the Chassis Power Administrator privilege can perform all power-related operations.
They can control chassis power operations, including power on, power off, and power cycle.
NOTE: To configure power settings, the Chassis Configuration Administrator privilege is
needed.
This is a blanket privilege, granting a CMC user all rights to perform any operation on any servers
present in the chassis.
When a user with Server Administrator privilege issues an action to be performed on a server, the CMC
firmware sends the command to the targeted server without checking the privileges of a user on the
server. In other words, the Server Administrator privilege overrides any lack of administrator privileges
on the server.
Without the Server Administrator privilege, a user created on the chassis can only execute a command
on a server when all of the following conditions are true:
The same user name exists on the server.
The same user name must have the same password on the server.
The user must have the privilege to execute the command.
When a CMC user who does not have Server Administrator privilege issues an action to be performed
on a server, CMC sends a command to the targeted server with the user's login name and password. If
the user does not exist on the server, or if the password does not match, the user is denied the ability to
perform the action.
If the user exists on the target server and the password matches, the server responds with the
privileges of which the user was granted on the server. Based on the privileges responding from the
server, CMC firmware decides if the user has the right to perform the action.
Listed below are the privileges and the actions on the server to which the Server Administrator is
entitled. These rights are applied only when the chassis user does not have the Server Administrative
privilege on the chassis.
Server Configuration Administrator:
Set IP address
Set gateway
Set subnet mask
Set first boot device
Configure Users:
Set iDRAC root password
iDRAC reset
Server Control Administrator:
Power on
Power off
Power cycle
Graceful shutdown
Server Reboot
113

Hide quick links:

Advertisement

Table of Contents
loading