Managing and Monitoring Power

The PowerEdge VRTX chassis is the most power-efficient modular server enclosure. It is designed to include highly efficient power
supplies and fans, has an optimized layout for the air to flow more easily through the system, and contains power-optimized
components throughout the enclosure. The optimized hardware design is coupled with sophisticated power management capabilities
that are built into the Chassis Management Controller (CMC), power supplies, and iDRAC to allow you to further enhance power-
efficient server environment.
The Power Management features of the PowerEdge VRTX help administrators configure the enclosure to reduce power
consumption and to adjust the power as required specific to the environment.
The PowerEdge VRTX modular enclosure consumes AC power and distributes the load across all active internal power supply units
(PSUs). The system can deliver up to 4800 Watts of AC power that is allocated to server modules and the associated enclosure
infrastructure. However, this capacity varies based on the power redundancy policy that you select.
The PowerEdge VRTX enclosure can be configured for any of the two redundancy policies that affect PSU behavior and determine
how chassis Redundancy state is reported to administrators.
You can also control Power management through OpenManage Power Center (OMPC). When OMPC controls power externally,
CMC continues to maintain:
Redundancy policy
Remote power logging
Dynamic power supply engagement (DPSE)
OMPC then manages:
Server power
Server priority
System Input Power Capacity
Maximum Power Conservation Mode
NOTE: Actual power delivery is based on configuration and workload.
You can use the CMC web interface or RACADM to manage and configure power controls on CMC:
View power allocations, consumption, and status for the chassis, servers, and PSUs.
Configure power budget and redundancy policy for the chassis.
Execute power control operations (turn on, turn off, system reset, power-cycle) for the chassis.

Redundancy Policies

Redundancy policy is a configurable set of properties that determine how CMC manages power to the chassis. The following
redundancy policies are configurable with or without dynamic PSU engagement:
Grid redundancy
Power supply redundancy

Grid Redundancy Policy

The purpose of the Grid redundancy policy is to enable a modular enclosure system to operate in a mode in which it can tolerate AC
power failures. These failures may originate in the AC power grid, the cabling and delivery, or a PSU itself.
154