CHAPTER 4: INITIAL INSTALLATION

4.3 INSTALLATION SAFETY

To avoid potentially fatal shock hazard and possible damage to equipment, please observe the following precautions:
Š Test AC outlets at the workstation and monitor for proper polarity and grounding.
Š
NOTE: The AC inlet is the main disconnect.

4.4 SERIAL CONFIGURATION OF IP ADDRESS

The default IP address for Boxilla on leaving the factory is 192.168.1.24 and needs to be configured to an appropriate address for
where it will be deployed. To access the serial menu, connect to the DB9 connector on the front of the unit. The serial port has a fixed
configuration of:
Š Baud-Rate: 112.5 kBaud
Š
Š Data: 8 bits
Š
Š Stop-Bits: 1
Š
Š Parity: None
Š
Š XON/XOFF: None
Š
Once the connecting PC has the correct configuration, the following menu should appear when connected to Boxilla's serial port.
Select "Change IP address" by entering 1. Then follow the prompts to set the new IP address, Net Mask and Gateway IP address.