Procedure
Step 1 Remove an appropriate length of steel armor and insulation layer from the cable using a wire
stripper, as shown in Figure 4-7.
Figure 4-7 Stripping an RS485 communications cable (unit: mm)
Step 2 Remove the terminal block from the SmartLogger COM port, as shown in Figure 4-8.
Figure 4-8 Connecting the terminal block
Step 3 Insert the bare cable cores into the terminal block, as shown by (1) in Figure 4-9.
(2016-06-20)
Protection ports 2 and 6 and Surge ports 1 and 5 form an RS485 signal SPD port for protecting one
COM port. Protection ports 8 and 12 and Surge ports 7 and 11 form another RS485 signal SPD port
for protecting one more COM port.
An RS485 signal SPD port supports cables with a maximum cross sectional area of 2.5 mm
devices need to be connected to an RS485 port in parallel, use cables with a cross sectional area of 1
2
mm
, and connect no more than two cables to the same port.
For details about the definitions of SmartLogger COM ports, see Context in Connecting the
SUN2000 Using an RS485 Communications Cable of 4.4.1 Connecting the SUN2000.
Remove the terminal block using a flat-head screwdriver.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.