2.4.3 Connection of charging contacts

CAUTION
Only use original supplied transformer.
Transformer
Charging contact
10
CAUTION
The connections to the + and - terminals
of the bottom charging contacts must be
reversed as compared to those of the
other charging contacts. This is
necessary to enable the drive unit to
detect that it has reached the bottom of
the stairs and must stop. This is the so-
called reset point.
NOTE
For the parallel connection of multiple
charging contacts, the cables can be
connected with splice connector. When
there are several floors, the connection
can best be made at the junction.
Charging contact
Charging contact