DEVIreg™ Touch
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by us-
ing a separate connector.
Note: Always install the floor sensor in a conduit in the
floor.
3. Mount and reassemble the thermostat.
Fasten the thermostat to a socket or an exterior
wall box by driving the screws through the holes
in each side of the thermostat.
Put the frame on.
Click the display module back in place
Important: Do NOT press on the display screen when
clicking the display module back in place.
Installation Guide