Using the Avaya Remote Supervisor Adapter
Alerts
Figure 14: Warning and System Alerts
See
Table 4, Warning alerts,
Table 4: Warning alerts
Alphanumeric
Pager Code
10
11
12
13
36
on page 36 for an explanation of warning alerts.
Event
Action
Redundant
[default: Disabled]: Not used in the S8500 Media Server
power supply
configuration.
failure
Single fan
[default: Enabled]: Generates an alert if one fan fails.
failure
Temperature
[default: Enabled]: Generates an alert if any monitored
irregularity
temperature readings are outside the warning threshold. The
S8500 Media Server remains in service. To view the
threshold values associated with the temperature readings,
select System Health in the navigation pane. Under
Environmentals, Temperature, click Value. A window
opens that shows the warning reset, warning, soft shutdown,
and hard shutdown thresholds for temperatures associated
with the selected component.
Voltage
[default: Enabled]: Generates an alert if any monitored
irregularity
voltages are outside the warning threshold values. The
S8500 Media Server remains in service. To view the voltage
operating setting, select System Health in the navigation
pane. Under Environmentals, Voltages, click Value. A
window opens that shows the warning reset, warning, soft
shutdown, and hard shutdown thresholds for voltages
associated with the selected component.
Avaya Remote Supervisor Adapter User Guide