12.1.3 Settings

Function
Comfortable temp.
Programme
Economic temp.

12.1.4 Time program

Used to configure the time program steering central heating..
Description of the adjustment time program refer to chapter 10.4.

12.1.5 Service

WARNING!
Access the service is intended only for qualified technical personnel. The changes may
cause malfunction of the system.
Function
Comf. MAX pump temp.
Econ. MAX pump temp.
MIN Tch pump
Source
Temperature MAX
Mixer time
Hot water priority
Pump test
Mixer test
Circ. name
36
Desired temperature in the room during the heating.
Programs:
a. time - according to preset intervals
b. constant - regardless of the time intervals comfortable
temperature is maintained
c. disabled - off the heat
d. economic - in the rooms temperature is maintained the
economic
Desired temperature in the room outside the period of
heating.
Maximum outdoor temperature at which the circulating pump
can work in a comfortable range.
Maximum outdoor temperature at which the circulating pump
can work in a economic range.
Minimum temperature calculated for central heating at which the
circulating pump can be operated.
Specifies the source of energy for central heating circuit.
Maximum temperature for central heating.
Time of full opening of the mixer.
Priority for hot water of the heating circuit.
During heating hot water the central heating pump is not working.
Starts the pump regardless of other conditions.
Starts the mixer motor independently of the other conditions.
Gives name for the central heating circuit.
Description