Tboiler
Boiler temperature sensor
5 (F-oto)
Photocell
6 (Tbur)
The temperature sensor burner
Thw
The temperature sensor hot water
Troom
Room temperature sensor / regulator (CTP)
Tch
The temperature sensor central heating
Tout
Outdoor temperature sensor (CTZ)
12V
+12V output to supply optional equipment
5V
+5V output to supply optional equipment
7 GND
Mass electric to connect sensors
Description
A (CH)
Central heating circulating pump
B (HW)
Circulating pump for hot water
4 (Ign)
Burner igniter
C (Mo)
Opening the central heating mixer
D (Mc)
Closing the central heating mixer
3 (Blo)
Burner blower
E (Ftan)
Feeder tank, or if burning wood, it's blower
2 (Fbur)
Burner feeder
1 (N1)
Neutral separable such as by STB
STB
Protection STB
N
Neutral standing
PE
Protective
Burner's regulator can control:
- central heating pump
- 1-16 heating circuits (radiators or underfloor heating) controlled according to outside
temperature
- room's temperature
- hot domestic water pump
- mixing valve
Extra accesories for the controller:
- room sensor CTP-01
- hot domestic water sensor CT2/3.0
- central heating sensor CT2/3.0
- external module CAN I/O MC-1 (ex. for solar system, accumulation tank)
- outside sensor CT2
ATTENTION!
Extra accessories to the controller must be bought separetly as they're not included in
boiler package.
INPUTS
Explanation
OUTPUTS
Explanation