FLIR CM83 User Manual page 43

600 a true rms power clamp meter
Hide thumbs Also See for CM83:
Table of Contents

Advertisement

7 Technical specifications
Table 7.8 Active power: watts (DC/AC)
Function
DCW
ACW
1. The range is determined by the V/A range (9.999 kW: 100 V,100 A; 99.99 kW: 1000 V,100 A, or 100 V, 600
A; 599.9 kW: 1000 V, 600 A).
Overload protection: 1000 V
Accuracy defined for:
ACW:
Sine waves, ACV ≧ 10 V
Frequency 50–60 Hz, PF = 1.00.
DCW: DCV ≧ 10 V, DCA ≧ 5 A.
Table 7.9 Power factor
Function
PF
Overload protection: 1000 V
#T559825; r. AI/33557/33557; en-US
Range
1
9.999 kW (10 V, 5 A
min)
99.99 kW (10 V, 5 A
min)
599.9 kW (10 V, 5 A
min)
9.999 kW (10 V, 5 A
min)
99.99 kW (10 V, 5 A
min)
599.9 kW (10 V, 5 A
min)
, 600 A
.
rms
rms
, ACA ≧ 5 A
rms
rms
Range
–1.00 to 0.00 to +1.00
, 600 A
.
rms
rms
Accuracy
±(3% + 0.05 kW)
±(3% + 0.5 kW)
±(3% + 10 dgt)
±(3% + 10 dgt)
.
Accuracy
±3° ± 1 dgt