Table 10-2: Sdi Output Amplitude - Tektronix TG700 Service Manual

Tv signal generator platform
Hide thumbs Also See for TG700:
Table of Contents

Advertisement

HD3G7 HD 3 Gb/s SDI Video Generator Adjustment Procedures

Table 10-2: SDI output amplitude

Characterization
DMM Measurement
(typically 0.2880 V)
Oscilloscope Cycle RMS
(typically 116 mV)
Oscilloscope Cycle Mean
(typically 1 mV)
Sine wave RMS amplitude
(typically 116 mV)
Attenuation Factor
Adjustment Record
Expected direct (μ)
Signal 1 amplitude
Measured direct (μ)
(typically 328 mV)
Calculated corrected value
Signal 2 amplitude
Measured direct (μ)
(typically 328 mV)
Calculated corrected value
10–6
Print this table for use during the Adjustment Procedure.
Minimum
— —
— —
— —
2.35
Minimum
Before Adjustment
— —
776 mV
— —
776 mV
Value
Value
After Adjustment
— —
— —
TG700 TV Signal Generator Platform Service Manual
Maximum
— —
— —
— —
— —
2.55
Maximum
— —
— —
824 mV
— —
824 mV