Launch X-631 Plus User Manual page 39

Wheel aligner
Table of Contents

Advertisement

LAUNCH
1. Four-probe rode normal light mode (Normal
light-4);
2. Four-probe rod high light mode (High light-4);
3. Two-probe rod normal light mode (Normal
light-2);
4. Two-probe rod high light mode (High light-2).
These four kinds of mode are same with that on the
computer.
The start-up interfaces of the probe rods are different:
The main working interfaces are different:
Camber
Battery electricity Qty.
Toe-in
Operation Instructions for X-631+ Wheel Aligner
First, please enter into No PC Mode of X-631+ wheel
aligner.
After the probe rods entering the main working
interfaces, please press down the keys of [Back Light]
and [Run-out Compensation] at the same time, you
can enter the selection interface of No PC Mode.
There are four kinds of working modes for selection.
Press key [Previous] or key [Next] to select the
desired mode among these four modes. The mode
pointed by the arrow head is the mode selected
currently. After selecting working mode, please press
down key [Previous] and [Next] at the same time to
enter No PC Mode.
The above interface is the No PC Mode selection
interface. Move arrow head to point to the desired
item. After selecting working mode, please press
down key [Previous] and [Next] at the same time to
enter the prompt interface for four-probe rod working
mode of No PC Mode.
X-631/X-631+ Wheel Aligner
Fig.4.92
Probe rod label
Fig.4.93
Fig.4.94
Fig.4.95
After selecting working mode, please press down key
[Previous] and [Next] at the same time to enter No PC
Mode (Two-probe rod working mode).
On main probe rod, please press key [Back Light] and
key [Run-out Compensation] at the same time to exit
No PC Mode. The screen will display Exit NO PC
Mode.
Some Explanations about No PC Mode of X-631+
Wheel Aligner
1. The probe rod via which the system enters No
PC Mode is of the main probe rod. The main
probe rod can perform the control functions
(just like main unit) under No PC Mode.
2. One set of probe rods has one main probe rod
only.
3. The label of the main probe rod is included
with square brackets ([ ]). For example, [FL]:
It indicates that FL is of the current main
probe rod.
4. If this set of probe rods has had the main
probe rod, the other probe rod cannot be set
as the main probe rod once more. If you force
to do it, the error prompts will be displayed.
Error prompts: Setting failed! [XX] is Main bar.
5. After entering main working interface, the
camber data will usually be displayed. Only
after entering No PC Mode can the toe-in data
be displayed. The toe-in data will become
invalid after the system exits No PC Mode.
4-24
Operation Instructions
Fig.4.96
Fig.4.97
Fig.4.98
Fig.4.99