click the icon of [Probe Rod Update], the screen will
pop up a password inputting box as shown in Fig.4.57.
Fig.4.57
Enter the password (provided by Launch), and then
click [OK] button to enter the interface of Probe Rod
Update as shown in Fig.4.58.
Fig.4.58
Directly click the icon of the probe rod required to
update, the probe rod icon selected will be highlighted.
button
Click
operator to press, at the same time within the limited
period, the key combination of [Previous]+[Next] on the
control panel of the probe rod required to update, in
order to trigger the probe rod to accomplish the update
operation. The screen will prompt whether the probe
rod update is successful or not.
Caution:
The information such as calibration values, recognition
number, etc. of each probe rod is all stored inside the
memory of the probe rod itself. When replacing or
recalibrating the probe rod, it is required to use this
function to read the information stored inside the probe
rod and save it inside the computer host, in order to
realize the match between the probe rod and the
computer host.
Electronic Level Correction for Probe Rod
In the interface of [Probe Rod Maintenance], please
click the icon of [Electronic Level Correction for Probe
Rod], the screen will pop up a password inputting
dialog box. Enter the password (provided by Launch),
and then click [OK] button to enter the interface of
Electronic Level Correction for Probe Rod. The function
of probe rod electronic level correction is mainly used
for solving the problem of the disaccord between
X-631/X-631+ Wheel Aligner
the screen will prompt the
electronic level and mechanical level due to long-time
use of the probe rod. The interface is as shown in
Fig.4.59.
According to the prompts on the screen, adjust the
level bubble to the middle position. Click [OK] button
after finished. The screen will prompt whether
electronic level correction for the probe rod is
successful or not.
Caution:
Before performing the operation of electronic level
correction for probe rod, it must be ensured that the
communication of 4 probe rods is normal.
Calibration for Probe Rode
In the [Probe rod maintenance] interface, click the
, the screen will pop up a password
icon
inputting dialogue box. Enter password, and then click
[OK] button, the screen will display the interface as
shown in Fig.4.60.
Click [NEXT] button, the interface is as shown in
Fig.4.61.
4-17
Operation Instructions
Fig.4.59
Fig.4.60