Launch X-631 Plus User Manual page 30

Wheel aligner
Table of Contents

Advertisement

LAUNCH
Fig.4.47
Detailed Information of Probe Rod:
In the [Probe rod maintenance] interface, click the
icon
to enter the interface for the detailed
information of probe rod. This interface can directly
display the running status of 8 CCD sensors and 8
clinometers inside the 4 probe rods. The interface is as
shown in Fig.4.48.
Select probe
Fig.4.48
[Select probe rode]: One of the probe rods will be
displayed bright green after clicking the icon of this
probe rod.
[CCD status]: To display the coordinate and using status
of the 2 CCD sensors inside the probe rod selected.
[Inclinometer status]: To display the coordinate and
using status of the 2 inclinometers inside the probe rod
selected.
Operating procedures:
Directly click the probe rod you want to check in the
model figure at left side, the probe rod you have
selected will be highlighted, the current readings of the
four probe rods can be displayed in reading scale figure
at right side. If certain sensor cannot read data, it
indicates that this probe rod has been abnormal.
Status of probe rod:
In the [Probe rod maintenance] interface, click the
X-631/X-631+ Wheel Aligner
CCD status
linclinometer status
4-15
icon
to enter the interface of the probe status.
Status of probe rod is used to display the
communication status between probe rod and system.
The interface is as shown in Fig.4.49.
Fig.4.49
When communication between probe rod and system is
normal,
will be displayed on probe rod,
otherwise
will be displayed to indicate the faulty
communication.
Also the current status of electricity quantity in probe rod
can be displayed in the case of the communication
between the probe rod and system is normal,
respectively two kinds of status are as follows:
1. Full electricity
2. Low electricity
Self-test for the Measurement Accuracy of Probe Rod
In the interface of [Probe Rod Maintenance], please click
the icon of [Self-test for Measurement Accuracy of Probe
Rod], the system will enter the interface as shown in
Fig.4.50. The probe rod measurement accuracy self-test
function is used for testing whether toe-in and camber
values measured by the probe rod currently used are
correct or not, and tell client or after-sales service
personnel if the probe rod needs to be recalibrated.
Fig.4.50
Operation Instructions

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X-631

Table of Contents