[Unit setting]: Used to set the displayed unit system of
system data, two types of unit systems can be selected:
percentage degree system and degree/minute system.
[Unit setting for toe-in]: Aiming to the particularity of the
unit for toe-in, the system adds the units of mm and
inch.
Note:
If you want to use long measure as the unit of toe-in,
during performing standard measurement, the system
will require the operator to enter the diameter of the
tires when entering the operating interface of Select
Vehicle Model.
Report setting
Report setting can set the format type of the report
form. The interface is as shown in Fig.4.44.
Fig.4.44
[Report form 1]: Format 1 is for detailed report form,
which includes the items of Before Adjustment, After
Adjustment, Standard maximum and minimum values.
[Report form 2]: Format 2 is for concise report form,
which lists the data information before and after
adjustment only.
[Report form 3]: Format 3 is for fig report form. The
interface is as shown in Fig.4.45.
Fig.4.45
Select Language
The system has provided many languages to select.
X-631/X-631+ Wheel Aligner
4-14
The interface is as shown in Fig.4.46
Operating procedures:
Select your desired language, and then click
button, the system will restart and switch to the interface
with the language you selected.
Probe Rod Maintenance
This function has provided six operations.
Detailed information of probe rod: Used to view
the running status of sensor inside the probe rod.
Status of probe rod: Used to view the status of
communication and electricity quantity of probe rod.
Self-test for measurement accuracy of probe
rod: Used for testing whether toe-in and camber values
measured by the probe rod currently used are correct or
not, and tell client or after-sales service personnel if the
probe rod needs to be recalibrated.
Probe rod update: Mainly used for probe rod
update service performed by after-sales service
personnel.
Electronic level correction for probe rode:
Mainly used for solving the problem of the disaccord
between electronic level and mechanical level due to
long-time use of the probe rod.
Calibration for probe rod: Used to reset the
calibration value of probe rod.
The interface is as shown in Fig.4.47.
Operation Instructions
Fig.4.46