5.7.8 NETWORK SETUP

The NETWORK SETUP menu is used to set the parameters when the system is in a network subject to the monitoring
of a host. See Table 5-27 for parameter descriptions.
Parameters
S802
#UNITS
S803
TEAMWORK
S824
MON ADD
S825
MON T.O.
S825
MON H.S.
S831
CS CTRL
S831
CS STAT
S832
NW CTRL
S832
NW STAT
S835
MON PROT
S836
IP #1
S836
IP #2
S836
IP #3
S836
IP #4
S837
NM #1
S837
NM #2
S837
NM #3
S837
NM #4
Default
Sum of the calibrated value and return air humidity measured by digital scroll 2NTC
29°C
sensor. This value is engaged in the calculation
°C
Outdoor Sensor
+0.0K
Calibrated Outdoor Sensor
+0.0K
Calibrated value of temperature sensor A
°C
Calculated value corresponding to temperature sensor A
+0.0%
Calibrated value of humidity sensor A
44.0%
Calculated value corresponding to humidity sensor A
TH
Calibrated value of temperature sensor B
+0.0K
Type of temperature sensor B
°C
Calculated value corresponding to temperature sensor B
+0.0%
Calibrated value of humidity sensor B
44.0%
Calculated value corresponding to humidity sensor B
TH
Type of temperature sensor C
Free cooling temperature sensor. PTC or NTC sensor can be configured according to the
-
actual configuration
+0°C
Calibrated value of free cooling temperature sensor
°C
Calculated value of free cooling temperature sensor
NTC
Air supply temperature sensor. PTC or NTC sensor can be configured
+0.0K
Calibrated value of air supply temperature sensor
°C
Calculated value of air supply temperature sensor
+0.0K
Calibrated value of temperature sensor C
°C
Calculated value of temperature sensor C
+0.0%
Calibrated value of humidity sensor C
%
Calculated value of humidity sensor C
Table 5-27 Descriptions of NETWORK SETUP parameters
Default
Setting range
1
1 ~ 32
No
No, 1, 2
3
1 ~ 99
No
No, 1, 2
3
1 ~ 99
Save, Load,
No
No
Change
Change, Valid
Save, Load,
No
No
Valid
Change, Valid
Vlcty, HN,
Vlcty
IGM, No
192
168
-
254
1
255
255
-
255
0
Liebert.PEX2 Series Air Conditioner User Manual
Chapter 5 iCOM Controller
Description
Description
Range: 1 ~ 32
Range: No, 1, 2
Monitoring address No. of the unit
Monitoring Timeout
Monitoring Handshake
Save the parameter set through MON ADD to the iCOM controller.
'No' means not saved
Indication of the saving state of the parameter set through MON
ADD. 'Change' means that the parameter is changed but not saved.
'Valid' means that the setting is valid and saved
Save the parameter set through U2U GRP to the iCOM controller.
'No' means not saved
Indication of the saving state of the parameter set through U2U
GRP. 'Change' means that the parameter is changed but not saved.
'Valid' means that the setting is valid and saved
Host monitoring protocol setting. Range: Vlcty (Velocity uses
intelligent card), HN (Hironet), IGM (ECA2), No
Set IP address
Set subnet mask
63