OemRescanGaInput
This command is used to rescan the geo-address input pins and
reset the IPMB address according to the input value.
Action
Byte
Request
Response
OemTestFunction
Internal test purposes only.
OemSetBlueLEDLongBlinking
This command is used to enable or disable the slow blink of the
blue HotSwap LED when a voltage is detected to be over ±5% out
of range for five seconds (see Table 4-1 on page 22).
is set to enabled by default.
Action
Byte
Request
Response
116
Value
0
C0h
1
22h
0
Complete Code
1
New IPMB address
Value
0
C0h
1
31h
2
00h or 01h
0
Complete Code
Description
NetFn/LUN for OEM
OEM defined command
00h means OK
New IPMB address value
Description
NetFn/LUN for OEM
OEM defined command
00h: disable slow blink capability
01h: enable slow blink capability
00h means OK
This function
IPMI User Guide