Installation of at Register (Non Pre-Wired or Potted Only )

Neptune ARB
Neptune ProRead (ARB VI)
E-Coder (ARB VII)
®
ECRII
and ECRIII
R450 Wall and Pit MIU User's Manual
If connecting the MIU to a new ProRead (ARB VI) encoder register, or if a three-
conductor cable is already connected to a ProRead (ARB VI) encoder register,
ensure that the ProRead (ARB VI) register is programed for three-wire mode using
the ProRead (ARB VI) programmer and its RF/MIU 6, 8, or 10ID TDI format. This
can be accomplished through the ProRead (ARB VI) receptacle before removing
the receptacle.
1
Before wiring the pit encoder register, make sure the cable is long enough.
Then, when the installation is complete, the pit lid can be removed easily with-
out straining the cable.
2
Use only 22 AWG cable to make the connection from the encoder register to
the MIU.
3
Remove the terminal screw cover from the encoder register.
4
Strip off 3/4" of jacket from the cable, leaving only the three insulated wires.
5
Taking precautions not to nick or cut the insulation on the three wires, strip off
1/2" of insulation from each of the three wires.
Figure 5 Wiring a Neptune Encoder Register
Table 3 MIU Color Code for Wires
Encoder Register
®
III, IV, and V
®
6
If required, connect the 3 conductor wire to the encoder register's terminals
per the manufacturer's instructions. See Figure 5 and Table 3.
MIU Wire Color/ Encoder Terminal Marking
Black / B
Green / G
Black / B
Green / G
Black / R
Green / B
General Installation Guidelines
Red / R
Red / R
Red / G
7

Advertisement