GLASS REPLACEMENT
Gasket and glass cleaning products are available at local retail home centers. Manufacturers of cleaning
products include, A.W. Perkins Co. (www.Awperkins. Com) or rutland products (www.Rutland.Com). After
extensive use, the gasket material which provides glass and door seal may lose it's resiliency and will need to be
replaced. Inspect glass and door gaskets periodically to ensure proper seal; if gaskets become frayed or worn,
SERVICE HINTS continued ...
replace immediately. This unit's door uses a 1 1/8" diameter rope gasket.
GLASS REPLACEMENT PROCEDURE

DOOR GASKET REPLACEMENT

1. Ensure appliance is not in operation and is thoroughly cooled.
CAUTION: DO NOT OPERATE A STOVE THAT
2. Remove screw and glass clips. (See parts list and diagram.)
3. Remove glass from door frame.
IS MISSING DOOR GASKET MATERIAL. OVER
4. If glass is broken, carefully remove and discard each broken piece to avoid cuts. Discard window gasket.
FIRING AND UNSAFE OPERATING CONDI-
Replace window and gasket with original factory replacement parts.
TIONS MAY RESULT.
5. Replace new gasket starting at the bottom of glass working along edges, being sure to center gasket
channel on glass.
PROCEDURE:
6. Trim to length and butt ends together.
1. Ensure appliance is not in operation and is thor-
7. Perform replacement procedure in reverse order after replacing glass and gasket.
oughly cooled.
8. When replacing glass into door, be sure not to overtighten screws and clips.
2. Remove old door gasket and clean channel.

BLOWER MAINTENANCE

3. Using an approved, high temperature gasket ce-
The blower is maintenance free other than periodic cleaning. Lightly vacuum motor and air inlet to keep free
ment, apply a thin coat in bottom of channel.
of dust and dirt.
WIRING DIAGRAM - MODEL F-6 BLOWER OPTION
DANGER: SHOCK HAZARD. DISCONNECT
POWER SOURCE BEFORE INSTALLATION
AND WHENEVER SERVICING BLOWER
SERVICE HINTS

WIRING DIAGRAM

ASSEMBLY.
4. Starting at hinge side of door, work gasket into
channel around door unit, end butt and trim to
length.
5. Close door and allow three to four hours for cement
to set before firing appliance.
BLOWER MAINTENANCE
The optional blower is maintenance free other than
cleaning. Lightly vacuum motor and air inlet to keep free
of dust and dirt.
CAUTION: MOVING PARTS CAN CAUSE
INJURY. DO NOT OPERATE WITH COVER
REMOVED.
NOTICE: ANY REPLACE-
MENT WIRING MUST HAVE
E Q U I VA L E N T I N S U L A -
TION AND TEMPERATURE
RATING (105°C).
-20-