Rf340R - Siemens SIMATIC RF300 System Manual

Rfid-systems simatic sensors
Hide thumbs Also See for SIMATIC RF300:
Table of Contents

Advertisement

RF300 system planning
4.4 Installation guidelines
Reduction of field data: Transponder and RF340R reader
Table 4-5
Transponder
RF320T
Without metal
On metal; distance 20 mm
Flush-mounted in metal; distance
all-round 20 mm
RF340T
Without metal
on metal
Flush-mounted in metal;
distance all-round 20 mm
RF350T
Without metal
on metal
Flush-mounted in metal;
distance all-round 20 mm
RF360T
Without metal
On metal; distance 20 mm
Flush-mounted in metal;
distance all-round 20 mm
4-34
Reduction of field data by metal (in %): Transponder and RF340R
Reader RF340R
Without metal
on metal
100
100
80
100
80
70
100
70
60
100
90
70
System Manual, Release 04/2006, J31069 D0166-U001-A2-7618
flush-mounted
in metal
(20 mm surround)
95
80
90
75
70
60
95
85
80
70
70
70
95
80
65
65
60
60
95
85
90
75
60
60