Restored to Factory Setting( >Reset)
This option is used to restore all settings in the system menu to factory setting
values. Press [Enter] to restore to factory setting values. In this case, all set
values in the system will be restored to factory setting values, i.e., the (Def)
mark values.
Configure Power-On State( >Power-on)
When the power-on parameter is set as Rst, at each time of power on, the set
parameters of the power supply will be 0V, 0A and the power rated value. The
parameter setting values under Setup and Function menus will also be restored
to initial values.
On( Def )
External control mode and related parameter setting
Ext- Ctrl
Voltage( D
ef )
10V(Def)/5
V
Resistance
10k/5k
Off
On
Parallel
Parallel mode set up
Single
Master
Slave
Filter
Set the display filter frequency of the power supply
Low
Mid( Def)
Fast
Sense-Protec
Enable sense reversed protection function
t
Disable
Enable( D
ef)
Product information
Model
Model of power supply
Ver
Software version
SN
Serial number
Last Cal
calibration information for last time
Note
[Shift]
[P-set]
Press
+
( Menu) to view the menu items,press
[Esc]
operation.Besides,press
Copyright ©ITECH Electronics
Turn on static current function (clear
voltage mantissa)
Voltage setting mode selection
10V or 5V setting mode selection. select by
left/right key.
Resistance setting mode selection. 10K or 5K
setting mode selection, select by left/right
key.
Disable or enable this function. Select by
up/down key.
Single mode
Act as a master mode
Master Mount: total number of instruments
in parallel.
Act as a slave mode
Low speed frequency
Middle speed frequency
High speed frequency
Disable sense reversed protection function
V = 5V: The protect voltage value. Difference
between sense voltage and output voltage.
When exceeds the value, the protection will
be activated.
Delay = 0.1ms( Def ): Protect delay time.
button can enable you quit the function operation state.
Co., Ltd.
Function and Features
[Esc]
to quit menu
20